BS-2094AF LED Fluorescent Inverted Biological Microscope
Introduction
BS-2094 Series Inverted Biological Microscope are high level microscopes which are specially designed for medical and health units, universities, research institutes to observe cultured living cells. With innovative infinite optical system and ergonomic design, they have excellent optical performance and easy to operate features. The microscopes have adopted long life LED lamps as transmitted and fluorescent light source. Digital cameras can be added to the microscope on left side to take photos, videos and make measurement.
Details
Overview
Packaging & Delivery
Packaging Details:Strong Carton with Polyfoam Protection
Port:Beijing
Lead Time:Within 3-4 Weeks after Receiving Payment
Introduction
BS-2094 Series Inverted Biological Microscope are high level microscopes which are specially designed for medical and health units, universities, research institutes to observe cultured living cells. With innovative infinite optical system and ergonomic design, they have excellent optical performance and easy to operate features. The microscopes have adopted long life LED lamps as transmitted and fluorescent light source. Digital cameras can be added to the microscope on left side to take photos, videos and make measurement.
The main difference between BS-2094AF and BS-2094BF is that BS-2094BF has an intelligent illumination management system, the illumination intensity will automatically change after you change the objectives and make the microscope to get the best illumination effect, BS-2094BF also has a LCD screen to show the working mode like magnification, light intensity, transmitted or fluorescent light source, working or sleep etc.
Features
1. Excellent infinite optical system, Φ22mm wide field eyepiece, 45° inclined viewing head, more comfortable for observation.
2. Camera port is on left side, less disturb for operation. Light distribution (both): 100 : 0 (100% for eyepiece); 0 : 100 (100% for camera).
3. Long working distance condenser N.A. 0.30, Working distance: 75mm(with condenser), Working distance: 187mm (without condenser), available for extra high culture dishes. Condenser is detachable, without condenser, it is suitable for culture flask.
4. Large size stage, convenient for research. Stage Size: 170mm(X) × 250 (Y)mm, Mechanical stage moving range: 128mm (X) × 80 (Y)mm. Various petri-dish holders are available.
5. BS-2094B has an intelligent illumination management system.
(1) Coded Quintuple Nosepiece can memorize the illumination brightness of each objective. When different objectives are converted to each other, the light intensity is automatically adjusted to reduce visual fatigue and improve work efficiency.
(2) Use a dimming knob to achieve multiple functions.
Click: Enter standby(sleep) mode
Double click: light intensity lock or unlock
Rotation: Adjust brightness
Press + clockwise rotate: Switch to the transmitted light source
Press + contrarotate: Switch to the fluorescent light source
Press 3 seconds: Set the time of turning off the light after leaving
(3) Display microscope working mode.
The LCD screen in the front of the microscope can display the working mode of the microscope, including magnification, light intensity, sleep mode and so on.
6. The microscope control mechanism has a reasonable layout and easy to operate.
The frequently used control mechanisms of these microscopes are close to the user and in low-hand position. This kind of design makes operation more quickly and conveniently, and reduce the fatigue caused by the long observation. On the other hand, it reduces the airflow and dust caused by large amplitude operation, it is very effective to reduce the probability of sample pollution. It is a strong guarantee for the accuracy and repeatability of the experimental results.
7. The microscope body is compact, stable and suitable for clean bench. The microscope body has been coated with anti-UV material and can be placed into the clean bench for sterilization under UV lamp. The distance between the eye point to the operation button and the focusing knob of the microscope is relatively short, and the distance from the stage is far away. It is available to make the viewing head and operating mechanism outside, and stage, objectives and sample inside the clean bench. So realize cell sampling and operation inside and observing comfortably outside.
8. Phase Contrast, Hoffman Modulation Phase Contrast and 3D Emboss Contrast observation method are available with transmitted illumination.
(1) Phase contrast observation is a microscopic observation technique that produces a high-contrast microscopic image of a transparent sample by utilizing a change in refractive index. The advantage is that the details of live cell imaging can be obtained without staining and fluorescent dyes.
Application range: Living cells culture, Micro-organism, Tissue slide, cell nuclei and organelles etc.
(2) Hoffman Modulation Phase Contrast. With slant light, Hoffman phase contrast changes phase gradient into light intensity variety, it can be used to observe unstained cells and living cells. Giving 3D effect for thick samples, it can greatly reduce the halo in thick specimens.
(3) 3D Emboss Contrast. No need for expensive optical components, just add a contrast adjustment slider to achieve a pseudo 3D glare-free image. Both glass culture dishes or plastic culture dishes can be used.
9. LED Fluorescent attachment is optional.
(1) LED light makes fluorescent observation easier.
Fly-eye lens and Kohler illumination have provided a uniform and bright field of view, which is benefit to get high definition images and perfect details. Compared with traditional mercury bulb, the LED lamp has much longer working life, it saves money and has greatly improved the working efficiency. The problems of preheating, cooling and high temperature of mercury lamp have also been solved.
(2) Suitable for a variety of fluorescent dyes.
The LED fluorescent attachment has equipped with 3 fluorescent filter blocks, it can be applied to a wide range of dyes and capture clear high contrast fluorescence images.
(3) Light barrier plate(contrast shield).
The light barrier plate can be attached to the condenser and effectively block the external light, increase the contrast of the fluorescent image and provide a high quality fluorescent image. When need phase contrast observation, the light barrier plate is very convenient to be removed from the light path, avoiding influence on the quality of phase contrast.
Application
BS-2094 series inverted microscopes are used by medical and health units, universities, research institutes for observations of micro-organisms, cells, bacteria and tissue cultivation. They can be used for continuous observation of process of cells, bacteria grow and divide in the culture medium. Videos and images can be taken during the process. These microscopes are widely used in cytology, parasitology, oncology, immunology, genetic engineering, industrial microbiology, botany and other fields.
Specification
Item |
Specification |
BS-2094 A |
BS-2094 AF |
BS-2094 B |
BS-2094 BF |
|
Optical System |
NIS 60 Infinite Optical System, Tube length 200mm |
● |
● |
● |
● |
|
Viewing Head |
Seidentopf Binocular Head, Inclined at 45°, Interpupillary Distance 48-75mm, Left side camera port, Light distribution: 100: 0 (100% for eyepiece), 0:100 (100% for camera), Eyepiece Tube Diameter 30mm |
● |
● |
● |
● |
|
Eyepiece |
SW10×/ 22mm |
● |
● |
● |
● |
|
WF15×/ 16mm |
○ |
○ |
○ |
○ |
||
WF20×/ 12mm |
○ |
○ |
○ |
○ |
||
Objective (Parfocal distance 60mm, M25×0.75) |
NIS60 Infinite LWD Plan Achromatic Objective |
4×/0.1, WD=30mm |
● |
○ |
● |
○ |
10×/0.25, WD=10.2mm |
○ |
○ |
○ |
○ |
||
20×/0.40, WD=12mm |
○ |
○ |
○ |
○ |
||
40×/0.60, WD=2.2mm |
○ |
○ |
○ |
○ |
||
NIS60 Infinite LWD Plan Phase Contrast Achromatic Objective |
PH10×/0.25, WD=10.2mm |
● |
○ |
● |
○ |
|
PH20×/0.40, WD=12mm |
● |
○ |
● |
○ |
||
PH40×/0.60, WD=2.2mm |
● |
○ |
● |
○ |
||
NIS60 Infinite LWD Plan Semi-APO Fluorescent Objective |
4×/0.13, WD=17mm, cover glass=- |
○ |
● |
○ |
● |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
○ |
● |
○ |
● |
||
20×/0.45, WD=8mm, cover glass=1.2mm |
○ |
● |
○ |
● |
||
40×/0.60, WD=3.3mm, cover glass=1.2mm |
○ |
● |
○ |
● |
||
60×/0.70, WD=1.8-2.6mm, cover glass=0.1-1.3mm |
○ |
○ |
○ |
○ |
||
NIS60 Infinite LWD Plan Semi-APO Phase Contrast Objective |
4×/0.13, WD=17.78mm, cover glass=- |
○ |
○ |
○ |
○ |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
○ |
○ |
○ |
○ |
||
20×/0.45, WD=7.5-8.8mm, cover glass=1.2mm |
○ |
○ |
○ |
○ |
||
40×/0.60, WD=3-3.4mm, cover glass=1.2mm |
○ |
○ |
○ |
○ |
||
60×/0.70, WD=1.8-2.6mm, cover glass=0.1-1.3mm |
○ |
○ |
○ |
○ |
||
Nosepiece |
Quintuple Nosepiece |
● |
● |
|
|
|
Coded Quintuple Nosepiece |
|
|
● |
● |
||
Condenser |
Long Working Distance Condenser, N.A. 0.3, Working Distance 75mm (with condenser), 187mm (without condenser) |
● |
● |
● |
● |
|
Telescope |
Centering Telescope: used to adjust the center of phase annulus |
● |
● |
● |
● |
|
Phase Annulus |
10×-20×-40× Phase Annulus Plate (center adjustable) |
● |
● |
● |
● |
|
4× Phase Annulus Plate |
○ |
○ |
○ |
○ |
||
Stage |
Stage 170 (X)×250(Y) mm with glass insert plate (diameter 110mm) |
● |
● |
● |
● |
|
Attachable Mechanical Stage, X-Y Coaxial Control, Moving Rang: 128mm×80mm, accept 5 types of petri-dish holders, well plates and stage clips |
● |
● |
● |
● |
||
Auxiliary stage 70mm×180mm, used to extend the stage |
○ |
○ |
○ |
○ |
||
Universal Holder: used for Terasaki plate, glass slide and Φ35-65mm petri dishes |
● |
● |
● |
● |
||
Terasaki Holder: used for Φ35mm Petri Dish Holder and Φ65mm petri dishes |
○ |
○ |
○ |
○ |
||
Glass Slide and Petri Dish Holder Φ54mm |
○ |
○ |
○ |
○ |
||
Glass Slide and Petri Dish Holder Φ65mm |
○ |
○ |
○ |
○ |
||
Petri Dish Holder Φ35mm |
○ |
○ |
○ |
○ |
||
Petri Dish Holder Φ90mm |
○ |
○ |
○ |
○ |
||
Focusing |
Coaxial Coarse and Fine Adjustment, tension adjustment, Fine Division 0.001mm, Fine stroke 0.2mm per rotation, Coarse stroke 37.5mm per rotation. Moving Range: up 7mm, down 1.5mm; Without limitation can up to 18.5mm |
● |
● |
● |
● |
|
Transmitted Illumination |
3W S-LED, Brightness Adjustable |
● |
● |
● |
● |
|
EPI-Fluorescent Attachment |
LED illuminator, built-in Fly-eye lens, can be configured with up to 3 different LED light source and B, G, U fluorescent filter blocks |
○ |
● |
○ |
● |
|
LED light source and V, R, FITC, DAPI, TRITC, Auramine, mCherry fluorescent filter block |
○ |
○ |
○ |
○ |
||
Hoffman phase contrast |
Hoffman Condenser with 10×, 20×, 40× insert plate, centering telescope and special objective 10×, 20×, 40× |
○ |
○ |
○ |
○ |
|
3D Emboss Contrast |
Main emboss contrast plate with 10×-20×-40× will be inserted into condenser |
○ |
○ |
○ |
○ |
|
Auxiliary emboss contrast plate will be inserted into slot which is near viewing head |
○ |
○ |
○ |
○ |
||
C-mount Adapter |
0.5× C-mount Adapter (focus adjustable) |
○ |
○ |
○ |
○ |
|
1× C-mount Adapter (focus adjustable) |
● |
● |
● |
● |
||
Other Accessories |
Warm stage |
○ |
○ |
○ |
○ |
|
Light barrier plate(contrast shield), can be attached to the condenser and block the external light |
○ |
○ |
○ |
○ |
||
Dust cover |
● |
● |
● |
● |
||
Power Supply |
AC 100-240V, 50/60Hz |
● |
● |
● |
● |
|
Fuse |
T250V500mA |
● |
● |
● |
● |
|
Packing |
2cartons/set, Packing Size: 47cm×37cm×39cm, 69cm×39cm×64cm Gross Weight: 20kgs, Net Weight: 18kgs |
● |
● |
● |
● |
Note: ● Standard Outfit, ○ Optional